ASCII - Command | ANOUT2 | |||
Syntax Transmit | ANOUT2 [Data] | |||
Syntax Receive | ANOUT2 <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Integer8 | CANBus Object Number | 387F (hex) | |
DIM | PROFIBUS PNU | 1695 (dec) IND = 33 (dec) | ||
Range | 0 .. 9 | DPR | 895 (dec) | |
Default | 0 | |||
Opmode | All | Data Type Bus/DPR | Integer8 | |
Drive State | - | Weighting | ||
Start Firmware | 3.00 | |||
Configuration | Yes | Last Change of this Object | 2.9 | |
Function Group | analog I/O | EEPROM | Yes | |
Short Description | Configuration of the Analog Output 2 |
Description
Only S700 Configuration of analog output 2. The actual value is read via MONITOR2. The output provides various analog command values or actual values, depending on the selection in the operator software. Output resistor 2.2kOhm. |
||
Status | function | description |
0 | off | no output at monitor output 2 |
1 | n_actual | output of actual speed value (10 V = VLIM) |
2 | I_actual | output of actual current value (10V = IPEAK) |
3 | n_cmd | output of speed setpoint (10V = VLIM) |
4 | I_cmd | output of current command value (10V = IPEAK) |
5 | PE | output of position error (10V = PEMAX) |
6 | slot | output of the DPR-value throuht the monitor 2 (with DPR-Slotkarte). ab FW >= 5.38 |
7 | PFB | the actual position is set to the analog output. The scaling refers to the modulo-value ERND-SRND. the output value is calculated by: ANOUTx = 10V * (PFB-SRND)/(ERND-SRND) if SRND is 0, the range of ERND is +/-10V. If SRND is unequal 0, the range is output is asymmetric. with PFB=SRND the output value is = 0 and PFB=ERND the output vale is = 10V. |
8 | U_const=x | the constant value of AN2TRIG (in mV) is set to analog output 2 |
9 | I2T | output of I2T (10V = 100%) |