ASCII - Command | AN2TRIG | |||
Syntax Transmit | AN1TRIG [Data] | |||
Syntax Receive | AN2TRIG <Data> | Available in | ||
Type | Variable rw | MMI | Yes | |
ASCII Format | Integer32 | CANBus Object Number | 3881 (hex) | |
DIM | - | PROFIBUS PNU | 1697 (dec) IND = 33 (dec) | |
Range | Long Int | DPR | 897 (dec) | |
Default | 0 | |||
Opmode | All | Data Type Bus/DPR | Integer32 | |
Drive State | - | Weighting | ||
Start Firmware | 3.00 | |||
Configuration | No | Last Change of this Object | 2.1 | |
Function Group | analog I/O | EEPROM | Yes | |
Short Description | Scaling of the analog output 2 |
Description
With the parameter AN2TRIG, the analog value of the monitor output 2 can be scaled to a specified ratio. Irrespective of the function that has been configured with ANOUT2 for output 2, the output voltage is multiplied by the factor AN2TRIG. This corresponds to the following formula: Output voltage = Output of the function ANOUT2 * (AN2TRIG/100%) Example: ANOUT2 = 1 : output of the current velocity, scaling: 10V for VLIM AN2TRIG = 100% - output=10V for velocity=VLIM AN2TRIG = 50% - output=5V for velocity=VLIM (this corresponds to a voltage of 10V for velocity=2*VLIM) AN2TRIG = 200% - output=20V for velocity=VLIM (this corresponds to a voltage of 10V for velocity = VLIM/2) have a look to ANOUT2, VLIM |