| ASCII - Command | ENCTO | |||
| Syntax Transmit | ENCTO [Data] | |||
| Syntax Receive | ENCTO <Data> | Available in | ||
| Type | Variable rw | MMI | No | |
| ASCII Format | Integer32 | CANBus Object Number | 3543 (hex) | |
| DIM | ms | PROFIBUS PNU | 1667 (dec) IND = 1 (dec) | |
| Range | 100 .. 12000 | DPR | 67 (dec) | |
| Default | 2000 | |||
| Opmode | All | Data Type Bus/DPR | Integer32 | |
| Drive State | - | Weighting | ||
| Start Firmware | 0.73 | |||
| Configuration | No | Last Change of this Object | 2.1 | |
| Function Group | other commands | EEPROM | Yes | |
| Short Description | Encoder supply delay | |||
Description
| This parameter defines the time between the “encoder power supply on” and the reading of the encoder parameter channel. |