ASCII - Command | EN22CNFG | |||
Syntax Transmit | EN22CNFG [Data] | |||
Syntax Receive | EN22CNFG <Data> | Available in | ||
Type | Variable rw | MMI | No | |
ASCII Format | Integer16 | CANBus Object Number | 390F (hex) | |
DIM | - | PROFIBUS PNU | 1839 (dec) IND = 33 (dec) | |
Range | 0 .. 3 | DPR | 1039 (dec) | |
Default | 1 | |||
Opmode | All | Data Type Bus/DPR | Integer16 | |
Drive State | Disabled + Reset (Coldstart) | Weighting | ||
Start Firmware | 5.91 | |||
Configuration | Yes | Last Change of this Object | 2.13 | |
Function Group | feedback | EEPROM | Yes | |
Short Description | Config.parameter for ENDAT 2.2 additional information |
Description
This parameter is a bit variable. Setting a bit activates the reading of the corresponding ENDAT2.2 additional information. Bit 0 = 1 Reading in the diagnostic information (evaluation values) Bit 1 = 1 Reading the additional information 1 Bit 2 = 1 Reading the additional information 2 Setting a bit to 0 inhibits the reading of the associated additional information |